IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Chemistry
  • Volume:29 Issue:1
  • Determination of Trace Copper by FAAS after Solid Phase Extraction and Preconcentration onto Amberli...

Determination of Trace Copper by FAAS after Solid Phase Extraction and Preconcentration onto Amberlite XAD-2 Loaded with Nitroso-R Salt

Authors : Mohammad Ali TAHER, Sayed Ziae Mohammadi
Pages : 17-26
View : 18 | Download : 9
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :A procedure for the separation and preconcentration of trace amounts of copper is proposed. It is based on the adsorption of copperinsert ignore into journalissuearticles values(II); ions solution onto a column of Amberlite XAD-2 resin loaded with disodium 1-nitroso-2-naphthol-3, 6-disulfonate insert ignore into journalissuearticles values(nitroso-R salt);. Copper is quantitatively retained on the column in the pH range 5.5-7.8 at a flow rate of 2 mL min-1. The copper complex eluted with 5 mL of dimethylformamide insert ignore into journalissuearticles values(DMF); and copper was measured by flame atomic absorption spectrometry insert ignore into journalissuearticles values(FAAS); at 324.8 nm. In this case, 0.10 m g of copper can be concentrated in the column from 800 mL of aqueous sample, where its concentration is as low as 0.125 ng mL-1. Eight replicate determinations of 1.0 m g mL-1 of copper in the final DMF solution gave a relative standard deviation of 1.8%. The sensitivity for 1% absorption was 27.5 ng mL-1. The interference of a large number of anions and cations was studied and the optimized conditions developed were utilized for the trace determination of copper in various environmental and standard samples.
Keywords : Amberlite XAD 2, flame atomic absorption spectrometry, solid phase extraction of copper, standard alloys and biological samples

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025