  • All Solid-State Contact Lead(II) Ion-selective PVC Membrane Electrode Using Dimethylene Bis(4-methyl...

All Solid-State Contact Lead(II) Ion-selective PVC Membrane Electrode Using Dimethylene Bis(4-methylpiperidinedithiocarbamate) Neutral Ionophore

Authors : İbrahim IŞILDAK
Pages : 389-394
View : 16 | Download : 11
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :All solid-state contact PVC membrane electrodes for leadinsert ignore into journalissuearticles values(II); ion were developed by using dimethylene bisinsert ignore into journalissuearticles values(4-methylpiperidinedithiocarbamate); as neutral carrier and nitrophenyloctyl ether or dioctylsebacate as plasticizers. Response properties of the all solid-state contact PVC membrane electrode prepared with nitrophenyloctyl ether were better than those of the membrane electrode prepared with dioctylsebacate. The nitrophenyloctyl ether plasticized the all solid-state contact PVC membrane electrode and exhibited a good linear response of 30 mV/decade for leadinsert ignore into journalissuearticles values(II); ion within the concentration ranges \insert ignore into journalissuearticles values( 0.1-5\times10-6 \); mol dm\insert ignore into journalissuearticles values( -3 \); leadinsert ignore into journalissuearticles values(II); nitrate, good selectivity over alkali, alkali-earth and transition metal ions including copperinsert ignore into journalissuearticles values(II); ion by a factor of at least 10\insert ignore into journalissuearticles values( 3 \);, 10\insert ignore into journalissuearticles values( 4 \); and 10\insert ignore into journalissuearticles values( 2 \); respectively, and a short response time. The useful pH range was between 2.0 and 6.0.
Keywords : All solid state contact, lead II, ion selective membrane electrode, Dimethylene bis 4 methylpiperidinedithiocarbamate, Ionophore

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.