IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Chemistry
  • Volume:43 Issue:1
  • Rapid and on-site electrochemical detection of bisphenol A and arsenic in drinking water using a nov...

Rapid and on-site electrochemical detection of bisphenol A and arsenic in drinking water using a novel electrode array

Authors : Yildiz ULUDAĞ, Zehra ÖLÇER, Canan DOĞAN, Turghun MUHAMMAD, Zeynep ALTINTAŞ
Pages : 239-250
View : 14 | Download : 5
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :The paper describes a novel dip-and-gauge hand-held sensor device for the rapid, cost-effective, and on-site detection of bisphenol A and arsenic in drinking water samples. Different working electrode diameters ranging from 1.5 mm to 4 mm were designed and fabricated to construct a new electrochemical biosensor. The sensor was employed for the chronoamperometric detection of bisphenol A and voltammetric determination of arsenic in drinking water samples. Bisphenol A measurements resulted in a detection limit of 10 ng mL$^{-1}$ with a linear range of 0-4000 ng mL$^{-1}$. Baby products and bottles have to be completely free of bisphenol and hence a liquid-phase microextraction method has been developed to reduce the detection limit further to 0.6 ng mL$^{-1}$. Arsenic detection was investigated in the concentration range of 0.4-250 ng mL$^{-1}$ with a detection limit of 1.9 ng mL$^{-1}$. The current study showed that the designed electrode array allows low detection limits insert ignore into journalissuearticles values(below threshold levels);, although a bare gold surface is used for the study. Hence, together with a hand-held sensor device that works by simply dipping the sensor chip into a water container, this cost effective system has the potential to be used either by household consumers or for on-site inspection purposes.
Keywords : Electrode array, bisphenol, arsenic, amperometry, voltammetry, hand held sensor

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025