IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Chemistry
  • Volume:43 Issue:5
  • Magnetic solid-phase extraction based on Coriolus versicolor-immobilized $\gamma $-Fe$_{2}$O$_{3}$ n...

Magnetic solid-phase extraction based on Coriolus versicolor-immobilized $\gamma $-Fe$_{2}$O$_{3}$ nanoparticles for preconcentration and determination of Al(III) in water and food samples

Authors : Sadin ÖZDEMİR, Mustafa Serkan YALÇIN, Ersin KILINÇ, Mustafa SOYLAK
Pages : 1217-1228
View : 21 | Download : 7
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :A method for preconcentration of Alinsert ignore into journalissuearticles values(III); prior to its determination by inductively coupled plasma-optical emission spectrometry insert ignore into journalissuearticles values(ICP-OES); was developed because the sensitivity of ICP-OES is insufficient for trace-level measurement of Alinsert ignore into journalissuearticles values(III);. The method is based on the use of Coriolus versicolor}-immobilized $\gamma $-Fe$_{2}$O$_{3}$ magnetic nanoparticles as a solid phase sorbent. The best experimental conditions were found as pH 6.0, 2.0 mL/min flow rate, 100 mg amount of C. versicoloron 150 mg of $\gamma $-Fe$_{2}$O$_{3}$ nanoparticles, and 500 mL of sample volume. The Alinsert ignore into journalissuearticles values(III); absorbed on biosorbent was eluted with 5.0 mL of 1.0 mol/L HCl. Limit of detection, limit of quantitation, linear range, correlation coefficient, relative standard deviation, and preconcentration factor were achieved as 0.03 ng/mL, 0.11 ng/mL, 0.2 to 20 ng/mL, 0.9994, 3%, and 100, respectively. Alinsert ignore into journalissuearticles values(III); was preconcentrated in different water and food samples after successful results were achieved in the case of certified reference samples.
Keywords : Aluminum, food, preconcentration, biosorbent, magnetic solid phase extraction, ICP OES

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025