Ionic liquid-based graphene oxide-coated fiber for headspace-solid phase microextraction of polycyclic aromatic hydrocarbons in water samples

Authors : Pelin ERDEM, Paniz TASHAKKORI, Melek MERDİVAN, Serap Seyhan BOZKURT
Pages : 1383-1397
View : 23 | Download : 9
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :Ionic liquid insert ignore into journalissuearticles values(IL); containing amino and vinyl terminated imidazolium cation and bis[insert ignore into journalissuearticles values(trifluoromethyl);sulfonyl] imide anion-functionalized graphene oxide insert ignore into journalissuearticles values(GO); coating material was prepared and coated on a stainless steel wire by a sol-gel technique for headspace-solid phase microextraction insert ignore into journalissuearticles values(HS-SPME);. Its extraction performance was checked by HS-SPME of polycyclic aromatic hydrocarbons insert ignore into journalissuearticles values(PAHs); coupled to gas chromatography with mass spectrometry insert ignore into journalissuearticles values(GC-MS);. The extraction capability of the IL-functionalized GO-coated fiber was comparable with that of the commercial fibers of polydimethylsiloxane insert ignore into journalissuearticles values(PDMS); and polydimethylsiloxane/carboxen/divinylbenzene insert ignore into journalissuearticles values(PDMS/CAR/DVB);. Under the optimized conditions, such as extraction temperature, extraction time, and salting-out, the proposed HS-SPME-GC-MS method presented a wide working range from 0.003 to 40 $\mu $g L$^{-1\, }$with a correlation coefficient higher than 0.996, low detection limits from 1 to 5 ng L$^{-1}$, and good precision less than 7%. The fiber-to-fiber repeatability was in the range of 0.2%-6.9%. The recoveries for 8 PAHs using the novel and commercial fibers in tap and seawater samples were obtained very close to each other and were in the range of 75.4% to 116.0%.
Keywords : Graphene oxide, ionic liquid, SPME, GC MS, PAH, sol gel, water samples

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.