IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Electrical Engineering and Computer Science
  • Volume:22 Issue:1
  • Spatiotemporal realization of an artificial retina model and performance evaluation through ISI- and...

Spatiotemporal realization of an artificial retina model and performance evaluation through ISI- and spike count-based image reconstruction methods

Authors : İrfan KARAGÖZ, Mustafa ÖZDEN
Pages : 223-241
Doi:10.3906/elk-1206-61
View : 16 | Download : 6
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :Development of an artificial retina model that can mimic the biologic retina is a highly challenging task and this task is an important step in the development of a visual prosthesis. The receptive field structure of the retina layer is usually modeled as a 2D difference of Gaussian insert ignore into journalissuearticles values(DOG); filter profile. In the present study, as a different approach, a retina model including a 3D 2-stage DOG filter insert ignore into journalissuearticles values(3D-ADOG); that has an adaptively changing bandwidth with respect to the local image statistic is developed. Using this modeling, the adaptive image processing of the retina can be realized. The contribution of the developed model in terms of the image quality is evaluated via simulation studies using test images. The first simulation results, including only the spike count-based reconstruction for a test video sequence, were previously published. In this study, in addition to the spike count-based reconstruction, the interspike interval measure is also used in the simulation study. The reconstruction results are compared using the statistical parameters of the mean squared error insert ignore into journalissuearticles values(MSE);, universal quality index insert ignore into journalissuearticles values(UQI);, and histogram similarity ratio insert ignore into journalissuearticles values(HSR);, which characterize the image likelihood. To evaluate the performance of the model versus time, time-dependent changes in the MSE, HSR, and UQI parameters are obtained and compared to the standard model. From these results, it is concluded that the 3D-ADOG filter-based retina model preserves the spatial details of the image and produces a larger number of different gray tone levels, which are important for the visual perception of an image, in comparison with the well-known classical DOG filter-based retina model. The retina implant systems based on this model can provide better visual perception for implant recipients.
Keywords : Image processing, retina modeling, artificial sight systems

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025