Minimum number of permanent-magnet synchronous generators for coordinated low-voltage ride-through of induction generators in hybrid wind farms

Authors : SHENGHU LI, RUI AN
Pages : 4970-4983
View : 18 | Download : 7
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :Coordinated low-voltage ride-through insert ignore into journalissuearticles values(LVRT); of induction generators insert ignore into journalissuearticles values(IGs); utilizing the excessive reactive power of permanent magnet synchronous generators insert ignore into journalissuearticles values(PMSGs); in hybrid wind farms is attractive due to saving investments on shunt compensators. The existing research is mainly based on dynamic simulations to given scenarios and does not quantify the necessary capacity and number of PMSGs. This paper newly proposes an analytical model to quantify the minimum number of the PMSGs for coordinated LVRT. The critical voltage at the point of common coupling insert ignore into journalissuearticles values(PCC); leading to slip instability of the IGs is quantified. To avoid instability, necessary var support from the PMSGs to improve the PCC voltage above the critical value is proposed. With the improved var control to the grid-side converter insert ignore into journalissuearticles values(GSC);, the minimum number of PMSGs is determined. Numerical results are provided to validate any error of the proposed model, which shows that voltage drop at the PCC, power capability of the PMSGs, and control strategy of the GSC are the critical factors for coordinated LVRT.
Keywords : Low voltage ride through, coordinated low voltage ride through, induction generator, permanent magnet synchronous generator, critical voltage, grid code

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.