IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Electrical Engineering and Computer Science
  • Volume:25 Issue:3
  • Error sources and measurement uncertainties in outdoor testing of BIPV modules

Error sources and measurement uncertainties in outdoor testing of BIPV modules

Authors : KIVANÇ BAŞARAN
Pages : 1840-1851
View : 15 | Download : 8
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :Although building-integrated photovoltaic insert ignore into journalissuearticles values(BIPV); systems have great potential, investment in this field is not at the desired level. There are two main reasons for this: the lack of technical analysis and economic reasons. Manufacturers and investors utilize datasheets of modules to determine the systems performance, which is determined at standard test conditions insert ignore into journalissuearticles values(STCs);. However, there are apparent differences between STCs and outdoor measurements. Most studies in the field of BIPV system analysis have only focused on long-term outdoor measurements. Besides that, uncertainty of measurements is necessary to achieve scientific results. The aim of this study is to emphasize the importance of measurement uncertainty, to describe how measurement uncertainties are calculated, and to find out the uncertainty of an outdoor BIPV measuring system. In this study, different roof-integrated photovoltaic systems with 15$^{\circ}$, 30$^{\circ}$, and 45$^{\circ}$ inclination angles were tested in the Fraunhofer Institute for Wind Energy and Energy System Technology measurement field. Maximum power point current, voltage, power, and temperature of each system were measured. The uncertainty of current, voltage, and temperature was calculated as 0.29%, 0.05%, and 1.15%, respectively.
Keywords : Building integrated photovoltaic, error, measurement uncertainty, Type A and B uncertainty

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025