  • Volume:25 Issue:5
  • Calculation of creepage discharge safety factors against the tangential component of electric fields...

Calculation of creepage discharge safety factors against the tangential component of electric fields in the insulation structure of power transformers

Authors : ARSALAN HEKMATI
Pages : 3487-3500
View : 13 | Download : 9
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :Creepage discharges are a main cause of insulation damage in power transformers during repeated tests or during operation. In this paper, a hazardous region in the insulation structure of power transformers insert ignore into journalissuearticles values(the interface between solid and liquid insulation at the top edge of a high-voltage electrode); is considered, and the impact of a very important factor of the surface discharge initiation and propagation insert ignore into journalissuearticles values(the tangential component of the electric field); on the strength of the insulation structure is investigated in power transformers. Insulation system reliability against this tangential component is presented as a safety factor. Two methods based on cumulative stress characteristics and breakdown probability are proposed for safety factor calculation and for the recognition of weak insulation regions. These methods provide essential information on insulation system design and optimization for reducing insulation deteriorations. A case study is performed on the insulation structure of a power transformer that failed during a test at the Iran Transfo Corporation. The redesigned transformer has shown no test failures in the past 10 years.
Keywords : Insulation structure, power transformer, safety factor, creepage discharge

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.