IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Electrical Engineering and Computer Science
  • Volume:26 Issue:4
  • Performance estimation and analysis of power line communication using single-ended loop testing

Performance estimation and analysis of power line communication using single-ended loop testing

Authors : Bharathi MAYILSWAMY, Amsaveni AVINASHIAPPAN
Pages : 2029-2042
View : 11 | Download : 8
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :Using the electricity infrastructure for broadband data transmission is known as power line communication insert ignore into journalissuearticles values(PLC);. The quality of broadband connectivity over a power line is a strong function of the line topology. Two-step hybrid single-ended loop testing insert ignore into journalissuearticles values(SELT); to estimate the open port loop topology of power lines is discussed in this paper. Correlation time domain reflectometry insert ignore into journalissuearticles values(CTDR); at different sockets is used to construct the initial topology. Optimization-based frequency domain reflectometry insert ignore into journalissuearticles values(FDR); is employed to ascertain more accurate power line topology. The discussed method has the advantage of reusing the existing DSL modem for the measurement and no prior knowledge is needed for the topology estimation. This method is validated for a wide range of line topologies with different numbers of bridge taps. The performance of the estimated topology is calculated using two-port network theory and the influence of the bridge taps on the performance of the line is analyzed.
Keywords : Single ended loop testing, correlation time domain reflectometry, frequency domain reflectometry, hybrid method, power line topology, capacity

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025