  • Fast adaptive reclosing in double-circuit transmission lines for improving power system stability ba...

Fast adaptive reclosing in double-circuit transmission lines for improving power system stability based on harmonic analysis scheme

Authors : Mohsen JANNATI, Alı Akbar AKBARI
Pages : 1164-1178
Doi:10.3906/elk-1907-161
View : 17 | Download : 7
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :An appropriate method is proposed for identifying permanent faults from transient faults in double-circuit transmission lines. This method could be used in adaptive single phase auto-reclosures in order to diagnose between permanent and transient faults, determine extinguishing time of the secondary arc, and calculate issuing time of reclosing commands during the occurrence of transient single phase to ground faults. The proposed method is based on harmonic analysis of the adjacent healthy circuit and could be an effective solution for blocking permanent disconnection of the power flow, improving stability, and maintaining the power network synchronism. In this paper, transient and permanent faults are simulated on a typical power system, and then current harmonics of the healthy circuit terminal are extracted and finally the proposed index for identifying the fault type is applied. In the case of transient faults, this method determines the minimum time needed for a fast successful adaptive reclosing in the network and thus prevents instability and nonsynchronism in both sides of the transmission line. Results of the various simulations run in EMTP-RV verifies accurate performance of the proposed approach.
Keywords : Transient and permanent faults, double circuit transmission lines, single phase auto reclosure, EMTP RV

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.