IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Turkish Journal of Engineering and Environmental Sciences
  • Volume:28 Issue:5
  • Treatment of Gaseous Trichloroethylene by a Sequential (Biological/Chemical) Reactor System

Treatment of Gaseous Trichloroethylene by a Sequential (Biological/Chemical) Reactor System

Authors : Ulaş TEZEL
Pages : 289-296
View : 14 | Download : 8
Publication Date : 0000-00-00
Article Type : Research Paper
Abstract :The treatment of gaseous trichloroethylene insert ignore into journalissuearticles values(TCE); by biotic and abiotic removal mechanisms in a sequential insert ignore into journalissuearticles values(biological/chemical); reactor system was investigated. The reactor system consisted of a granular anaerobic mixed culture packed biofilter followed by an elemental iron metal insert ignore into journalissuearticles values(Feinsert ignore into journalissuearticles values(0);); packed column in series. The effect of empty bed contact time insert ignore into journalissuearticles values(EBCT); and influent TCE concentration on the TCE removal performance of the system were investigated. In order to determine the effect of EBCT on the TCE removal performance of the system and the optimum EBCT for this system, EBCTs from 0.25 to 2.5 h were applied. The system was fed with 170.6 \pm 28.5 ppmv of average influent TCE concentration, 5000 ppmv of H2, 2000 ppmv of CO2 and 6000 ppmv of N2. Optimum EBCT for the system was determined as 1 h. The TCE removal performance at this EBCT was 31.0 \pm 2.8% in the biofilter, 80.9 \pm 6.9% in the Feinsert ignore into journalissuearticles values(0); packed column and 86.7 \pm 5.2% in the overall system. Only ethylene and ethane were detected in the effluent of the system as reduction by-products. In addition, the performance of the system was not altered between the initial TCE concentrations of 150 and 650 ppmv at 1h of EBCT.
Keywords : Biofilter, Fe 0, packed column, Reductive dechlorination, Trichloroethylene

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025