  • AURUM Mühendislik Sistemleri ve Mimarlık Dergisi
  • Volume:7 Issue:1
  • A MODIFIED SALP SWARM OPTIMIZATION ALGORITHM BASED ON THE LOAD FREQUENCY CONTROL OF MULTIPLE-SOURCE ...

A MODIFIED SALP SWARM OPTIMIZATION ALGORITHM BASED ON THE LOAD FREQUENCY CONTROL OF MULTIPLE-SOURCE POWER SYSTEM

Authors : Anas Mahdi ALZUBAIDI, Galip CANSEVER
Pages : 73-84
View : 23 | Download : 38
Publication Date : 2023-06-30
Article Type : Research Paper
Abstract :This work proposes a modified Salp Swarm Optimization Algorithm insert ignore into journalissuearticles values(SSA); for addressing a multi-source power state\`s Load Frequency Control insert ignore into journalissuearticles values(LFC);. A controller parameter tuning of the SSA method and its application to the LFC of a multi-source power system with several power generating sources. Derive to the controller parameters, a single area telecommunications device that permits two power system with integrated controlles according to each unit is considered first, and the SSA approach is used. The tunned SSA algorithm is used to optimize the integral insert ignore into journalissuearticles values(I);, proportional integral insert ignore into journalissuearticles values(PI);, and proportional integral derivative insert ignore into journalissuearticles values(PID); parameters. The research is expanded to include a multi-area multi-source power system, as well as an HVDC link is proposed for connectivity of two regions in addition to the current AC point of intersection. This same tunned SSA method is used to improve the parameters of the Integral insert ignore into journalissuearticles values(I);, Proportional Integral insert ignore into journalissuearticles values(PI);, and Proportional - integral - derivative Derivative insert ignore into journalissuearticles values(PID);. Consequently, the suggested system is shown to be resilient and unaffected by changes of the loading situation, system parameters, or SLP size.
Keywords : salp swarm algorithm SSA, Load Frequency Control LFC, Multi Source Power System, Integral Absolute Error IAE,

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.