IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Acta Materialia Turcica
  • Volume:4 Issue:4
  • Diffuse Optic Tomography (DOT) Techniques for Biomedical Imaging

Diffuse Optic Tomography (DOT) Techniques for Biomedical Imaging

Authors : Huseyin Ozgur KAZANCİ
Pages : 8-11
View : 17 | Download : 11
Publication Date : 2020-10-23
Article Type : Conference Paper
Abstract :Diffuse optic tomography insert ignore into journalissuearticles values(DOT); techniques are part of the classification of molecular biomedical optic imaging modality. DOT has the device instrumentation and mathematical image reconstruction parties. In device instrumentation part, electronic, optic and mechanic combinations are prepared for laser data acquisition processes. Basically, DOT devices have light source and photo detector units. Depend on the source and detector placement on imaging tissue surface, device geometry may be transmission through, back-reflected, cylindirical ring or spherical. Laser sources are illumination devices. Laser photons with specific wavelength are sent through tissue from tissue surface. Depend on the molecules’ biochemical structure, laser wavelength can be selected application specific. Molecules have different absorption coefficients depend on the laser wavelength. Detector units can be semiconductor PIN photodiodes, CCD or CMOS imagers. Different approaches can be used for geometrical DOT source-detector placements such that transmission through, back-reflected, cylindirical ring or spherical models. For instance, multi-sources and detectors might be placed like chessboard shape for back-reflected tissue imaging geometry. DOT imaging modality is also divided into three major branches depend on the run mode principle. Continuous Wave insert ignore into journalissuearticles values(CW);, Frequency Domain insert ignore into journalissuearticles values(FD);, and Time Resolved insert ignore into journalissuearticles values(TR); techniques are using different laser sources. CW technique is using steady state laser source. FD technique is using wide frequency range. TR technique is using picosecond insert ignore into journalissuearticles values(ps); or femtosecond insert ignore into journalissuearticles values(fs); pulsed laser source. All of these techniques are trying to investigate tissue molecule concentrations and spatial distributions by using acquired data in image reconstruction algorithm. Generalized image reconstruction algorithms are using mathematical inverse problem solution methods which might be back-projection method as an example of algebraic reconstruction technique insert ignore into journalissuearticles values(ART);, regularization methods as an example of Tikhonov-Morozov discrepancy method, or sub-space methods such as conjugated gradient insert ignore into journalissuearticles values(CG); methods.
Keywords : Biomedical optic imaging, diffuse optic tomography DOT, technique, transmission through, back reflected, cylindirical ring, continuous wave CW, frequency domain ins

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025