IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Clinical and Experimental Health Sciences
  • Volume:11 Issue:4
  • The Investigation of Tissue Composition Effects on Dose Distributions Using Monte Carlo Method in Pe...

The Investigation of Tissue Composition Effects on Dose Distributions Using Monte Carlo Method in Permanent Prostate Brachytherapy

Authors : Serhat ARAS
Pages : 769-774
Doi:10.33808/clinexphealthsci.884245
View : 17 | Download : 10
Publication Date : 2021-10-26
Article Type : Research Paper
Abstract :Objective: Radiation dose calculations in the prostate brachytherapy practices have very high importance in terms of the success of treatment. The purpose of the present study is to determine whether there is a significant dose difference between the radiation dose calculations performed in water medium and prostate cancer-diagnosed patients by using the Monte Carlo method. Methods: The radiation dose calculations were performed on 20 prostate patients by using the BrachyDose Monte Carlo code. Phantom geometry derived from real patients computed tomography insert ignore into journalissuearticles values(CT); data was created to use in dose calculations. Water material was assigned to all voxels within the prostate volume for dose comparison with CT derived phantom. 125I insert ignore into journalissuearticles values(Amersham, OncoSeed, 6711);, 103Pd insert ignore into journalissuearticles values(Theragenics Co., TheraSeed, 200); and 131Cs insert ignore into journalissuearticles values(IsoRay Medical); commercial brachytherapy seed models were used in dose calculations. Results: It was observed that there are significant dose differences between the water medium and the prostate tissue. The differences between D90 dose values in prostate tissue and water medium were calculated as 7.2-10.5%, 9.1-13.4% and 5.4-8.3% for 125I, 103Pd and 131Cs brachytherapy seed sources, respectively. Conclusions: It was concluded that material compositions of different organs and tissues in the human body should be considered for more accurate brachytherapy dose calculations.
Keywords : Brachytherapy, prostate cancer, tissue composition, Monte Carlo, brachydose

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025