IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Clinical and Experimental Health Sciences
  • Volume:13 Issue:4
  • Assessment of Micro-Gap in Hybrid Abutment-Crowns Fabricated with Different Materials

Assessment of Micro-Gap in Hybrid Abutment-Crowns Fabricated with Different Materials

Authors : Tuğçe Çetin, Yılmaz Umut Aslan
Pages : 871-875
Doi:10.33808/clinexphealthsci.1215298
View : 48 | Download : 99
Publication Date : 2023-12-29
Article Type : Research Paper
Abstract :Objective: The aim of this in vitro study is to evaluate the micro-gap changes in three dimensions after thermodynamic loading between hybrid abutment crowns made of different materials and implants with internal conical connection. Methods: A total of 10 morse cone connection implants (Straumann Bone Level Implant, Institut Straumann AG, Basel, Switzerland) were used. In this study, two study groups were formed using lithium disilicate glass-ceramic (LD) and polymethyl methacrylate (PMMA) in hybrid abutment-crown production (n=5). Hybrid abutment-crowns were fabricated by CAD/CAM system. Hybrid abutment crowns were designed and manufactured digitally. A 4-month of clinical cycle was applied to the samples in the chewing simulator. The micro-gap at the implant- abutment interface was visualized with micro-CT before and after thermodynamic loading. Micro-gap change was determined using these obtained images. For comparisons, independent t-test was used. Results: When comparing the micro-gap volumes before and after aging, no significant difference was observed between the LD and PMMA groups. The micro-gap increase after loading was 0.68 ±0.209 in the LD group and 0.45 ±0.373 in the PMMA group. Although the increase was higher in the LD group, there is no statistically significant difference between two groups. Conclusion: he micro-gap in the interface of implants and hybrid abutment crowns increased after aging. Hybrid abutment-crown material affected the micro-gap increase, but it was not statistically significant.
Keywords : Micro gap, hybrid abutment crown, implant abutment connection

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025