IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Current Research in Dental Sciences
  • Volume:26 Issue:1
  • FARKLI ASTAR VE KAİDE MATERYALLERİNİN KOMPOZİT REZİNİN MAKASLAMA BAĞLANMA DAYANIMINA ETKİSİ

FARKLI ASTAR VE KAİDE MATERYALLERİNİN KOMPOZİT REZİNİN MAKASLAMA BAĞLANMA DAYANIMINA ETKİSİ

Authors : Oğuzhan ALICI, Diğdem EREN, Gülşah Göktolga AKIN, Özden ÖZEL BEKTAŞ, Engin KARİPER
Pages : 0-0
View : 18 | Download : 8
Publication Date : 2016-10-25
Article Type : Research Paper
Abstract :Amaç: Bu çalışmanın amacı farklı astar ve kaide materyallerinin kompozit rezinin dentine bağlanma dayanımına etkisini incelemektir. Gereç ve Yöntem: Bu çalışmada 60 adet çürüksüz insan 3. molar dişi kullanıldı. Yüzeyel dentinin açığa çıkması için dişler okluzal yüzeye paralel olarak kesil- dikten sonra, örnekler farklı astar ve kaide materyalle- rini uygulamak üzere rastgele 6 gruba insert ignore into journalissuearticles values(n=10); ayrıldı. Grup 1: Kontrol, Grup 2: Kimyasal Sertleşen Kalsiyum Hidroksit, Grup 3: Işıkla Sertleşen Kalsiyum Hidroksit, Grup 4: Geleneksel Cam İyonomer Siman, Grup 5: Kapsül Cam İyonomer Siman, Grup 6: Rezin Modifiye Kalsiyum Silikat olarak düzenlendi. Kaide veya astar materyalleri, üretici firma talimatları doğrultusunda dentin yüzeylerine göre yerleştirildi. Daha sonra adeziv sistem insert ignore into journalissuearticles values(Clearfil SE Bond, Kuraray Medical Inc., Osaka, Japonya); ve kompozit rezin insert ignore into journalissuearticles values(Tetric-N-Ceram, Ivoclar Vivadent AG, Schaan, Lihtenştayn); materyallerin ve dentinin üzerine uygulandı. Hazırlanan örnekler makaslama bağlanma dayanımı testi için üniversal test makinasına yerleştirildi. Makaslama bağlanma dayanımı testi 1 mm/dk kafa hızında uygulandı. Veriler tek yönlü varyans analizi insert ignore into journalissuearticles values(ANOVA); ve Tukey HSD testleri kullanılarak değerlendirildi. İstatistiksel anlamlılık düzeyi p=0.05 olarak kabul edildi. Bulgular: Bağlanma dayanımı en yüksek kontrol grubunda görülürken kapsül cam iyonomer siman grubu diğer gruplara göre düşük bulundu. Makaslama bağlanma dayanımları karşılaştırıldığında 1. Grup ile 4., 5. ve 6. Grup arasında,  2. Grup ile 5. Grup arasında farklar istatistiksel olarak anlamlı bulundu insert ignore into journalissuearticles values(p<0.05);. Ayrıca 3. Grup ile diğer gruplar arasındaki farklar istatistiksel olarak anlamsız bulundu insert ignore into journalissuearticles values(p >0.05);. Sonuç: Bu çalışmanın sonuçlarına göre astar ve kaide materyalleri, kompozit rezinin dentine bağlanma dayanımını etkileyebilir. Anahtar Kelimeler: Dental adezivler, kalsiyum silikat, kompozit rezin THE EFFECT OF DIFFERENT LINER AND BASE MATERIALS ON THE SHEAR BOND STRENGTH OF COMPOSITE RESIN ABSTRACT   Aim: The purpose of this study was to investigate the effect of different liner and base materials on bond strength of composite resin to dentin. Material and Methods: 60 non-carious extracted human third molar were used in this study. After the teeth were sectioned parallel to the occlusal surface to expose superficial dentin, specimens were randomly divided into six groups insert ignore into journalissuearticles values(n=10); to apply different liner or base materials. The groups were set that Group 1: Control, Group 2: Chemical calcium hydroxide, Group 3: Light cured calcium hydroxide, Group 4: Conventi- onal glass ionomer cement, Group 5: Encapsulated glass ionomer cement, Group 6: Resin modified calcium silicate. Liner or base materials were placed on dentin surface according to manufacturer’s instructions. Then adhesive system insert ignore into journalissuearticles values(Clearfil SE Bond, Kuraray Medical Inc., Osaka, Japan); and composite resin insert ignore into journalissuearticles values(Tetric-N-Ceram, Ivoclar Vivadent AG, Schaan, Liechtenstein); were applied on materials and dentin. The prepared specimen were placed in a universal testing machine for shear bond strength test. Then, shear bond strength test was performed at a crosshead speed of 1.0 mm/min. Data were analyzed by using One-Way Variance analysis insert ignore into journalissuearticles values(ANOVA); and Tukey HSD tests. The level of statistical significance was accepted p=0.05. Results: While the control group showed higher bond strength, encapsulated glass ionomer cement group showed lower bond strength than the other groups. When comparing the mean shear bond strength, there are statistically significant differences between group 1 and group 4., 5., 6. also between group 2 and group 5 insert ignore into journalissuearticles values(p<0.05);. Moreover, there are no statistically significant differences between 3. groups and the other groups insert ignore into journalissuearticles values(p<0.05);. Conclusion: According to the results of this study, liner and base materials may affect  the bond strength of composite resin to dentin. Keywords: Dental adhesives, calcium silicate, composite resin
Keywords :

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025