IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Current Research in Dental Sciences
  • Volume:26 Issue:1
  • MİNEYE FARKLI YÜZEY PÜRÜZLENDİRME METOTLARIYLA YAPIŞTIRILMIŞ BRAKETLERİN MAKASLAMA AĞLANMA DAYANIMLA...

MİNEYE FARKLI YÜZEY PÜRÜZLENDİRME METOTLARIYLA YAPIŞTIRILMIŞ BRAKETLERİN MAKASLAMA AĞLANMA DAYANIMLARI

Authors : Fidan ALAKUŞ SABUNCUOĞLU, Şeyda ERŞAHAN, Ergül ERTÜRK
Pages : 0-0
View : 21 | Download : 9
Publication Date : 2016-10-25
Article Type : Research Paper
Abstract :Amaç: Bu in vitro çalışmanın amacı dört farklı pürüz- lendirme yönteminin ortodontik braketlerin makaslama bağlanma dayanımı üzerine etkisini incelemektir. Metod: Bu çalışmada 40 yeni çekilmiş üst 1. premolar insan dişi kullanıldı ve mine yüzey tedavi tipine bağlı olarak rastgele dört gruba ayrıldı insert ignore into journalissuearticles values(n=10);: I, asitle pürüzlendirme; II, Er:YAG lazer; III, Er:YAG lazer + asit pürüzlendirme; IV, alüminyum oksit ile kumlama. Dişler dikey bir pozisyonda kendi kendine sertleşen akrilik içerine gömüldü ve böylece kronları açığa çıktı Paslanmaz çelik premolar braketleri standart bir iş- lemle tüm dişlere yapıştırıldı ve tüm dişler SBS testine tabii tutuldu. Sonra, her bir örnek için artık adeziv indeksi insert ignore into journalissuearticles values(adhesive remnant index -ARI); değerlendirildi. Kırılma modları miktar olarak bir stereomikroskopla ve morfolojik olarak da bir tarama elektron mikroskopu insert ignore into journalissuearticles values(scanning electron microscope-SEM); altında değerlen- dirildi. İstatistiksel analiz anlamlılık seviyesi 0.05’de kararlaştırılarak tek yönlü varyans analizi ve Tukey çoklu karşılaştırma testi ile yapıldı. Bulgular: Her bir grup için ortalama makaslama test değerleri sırasıyla şöyledir: I, 10.21 ± 0.8; II, 9.33 ± 1.2; III, 13.46 ± 0.7; IV, 3.36 ± 0.6. III. grup insert ignore into journalissuearticles values(ErYAG lazer + asit pürüzlendirme); en yüksek SBS değerlerini gösterirken, IV. grup insert ignore into journalissuearticles values(kumlama); en düşük SBS değer- lerini gösterdi ve kumlama ve diğer gruplar arasında istatistiksel olarak anlamlı bir farklılık gözlendi. ARI skorlarının değerlendirilmesi III.grupta mine yüzeyinde daha fazla adezivin kaldığını gösterdi.  Sonuç: Mevcut bulgular yüzey pürüzlendirme için uygun parametrelerle Er:YAG lazerden faydalanmanın mümkün olduğudur. Anahtar Kelimeler: Makaslama bağlanma dayanımı, kumlama, Er-YAG lazer, asitle pürüzlendirme, ortodontik bağlanma. SHEAR BOND STRENGTHS OF BRACKETS BONDED TO ENAMEL WITH DIFFERENT SURFACE CONDITIONING METHODS ABSTRACT Aim: The purpose of this in vitro study is to evaluate the effect of four different conditioning methods on the shear bond strength insert ignore into journalissuearticles values(SBS); of orthodontic brackets. Methods: In this study 40 freshly extracted upper first premolar human teeth were used and randomly divided into four groups insert ignore into journalissuearticles values(n=10);, according to the type of the enamel surface treatment: I, acid etching; II, Er:YAG laser; III, Er:YAG  laser + acid-etching; IV, sandblasting with aluminum oxide. The teeth were embedded in self cure acrylic in a vertical position so that the crowns were exposed. Stainless steel premolar brackets were bonded to all teeth with a standard procedure and all teeth were subjected to SBS test. The adhesive remnant index insert ignore into journalissuearticles values(ARI); was then evaluated for each specimen. Failure modes were assessed quantitatively under a stereomicroscope and morphologically under a scanning electron microscope insert ignore into journalissuearticles values(SEM);. Statistical analysis was performed using one-way analysis of variance and the post hoc Tukey test, with the significance level set at 0.05. Results: Mean shear test values for each group were as follows: I, 10.21 ± 0.8; II, 9.33 ± 1.2; III, 13.46 ± 0.7; IV, 3.36 ± 0.6. While group III insert ignore into journalissuearticles values(ErYAG laser + acid-etched); showed the highest SBS values, group IV insert ignore into journalissuearticles values(sandblasting); showed the lowest SBS values and a statistically significant difference was observed between sandblasting and the other groups. The evaluation of ARI scores demonstrated more adhesive was left on the enamel surface with Group III. Conclusion:   The current findings indicate that it is possible to benefit from Er:YAG laser with appropriate parameters for surface conditioning.   Key-words: Shear bond strength, sandblasting, Er-YAG laser, acid-etching, orthodontic bonding
Keywords :

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025