- Current Research in Dental Sciences
- Volume:29 Issue:3
- FARKLI ÜNİVERSAL BAĞLAYICI AJANLARIN CAD/CAM SERAMİKLERİN KOMPOZİT REZİN İLE TAMİRİ SONRASI BAĞLANMA...
FARKLI ÜNİVERSAL BAĞLAYICI AJANLARIN CAD/CAM SERAMİKLERİN KOMPOZİT REZİN İLE TAMİRİ SONRASI BAĞLANMA KUVVETİNE ETKİSİ
Authors : Kübra CANTÜRK, Buket KARALAR, Ömer SAĞSÖZ, Nilgün SEVEN, Nurdan POLAT SAĞSÖZ, Yusuf ZİYA BAYINDIR
Pages : 381-386
Doi:10.17567/ataunidfd.528323
View : 15 | Download : 11
Publication Date : 2019-07-16
Article Type : Research Paper
Abstract :AMAÇ: Bu çalışmada iki farklı CAD/CAM seramiğe bir primer ve iki farklı bağlayıcı ajan uygulanarak kompozit rezinle tamir sonrası bağlanma kuvvetinin değerlendirilmesi amaçlandı. YÖNTEM: CAD/CAM seramik materyallerden insert ignore into journalissuearticles values(VITA Suprinity ve IPS e.max CAD); 30’ar adet örnek hazırlandı. Örnekleri elde etmek için yavaş hızlı testere insert ignore into journalissuearticles values(ISOMET 1000); kullanılarak seramik bloklardan 1 mm kalınlığında kesitler alındı. Daha sonra seramikler soğuk akriliğe sabitlenerek yüzeylerine 1dk boyunca %10’luk hidroflorik asit uygulandı. Primer uygulamasına göre seramikler iki gruba ayrıldı: BISCO Z-Prime-ZP ve primer kullanılmayan kontrol grubu-K. Uygulanan bağlayıcı ajanlara göre de seramikler 2 alt gruba daha ayrıldı: 3M ESPE Single Bond Universal-Sb, KURARAY Clearfil Universal Bond Quick -Qb insert ignore into journalissuearticles values(n=5);. 3M ESPE Single Bond Universal-Sb seramiklere 20 sn boyunca ovalama hareketi ile uygulanıp 5 sn hava ile seyreltildi ve LED ışık cihazı ile 10 sn polimerize edildi. KURARAY Clearfil Universal Bond Quick-Qb ise seramiklere 10 sn boyunca ovalama hareketi ile uygulanıp 5 sn hava ile seyreltildi ve LED ışık cihazı ile 10 sn polimerize edildi. Bir kompozit rezin insert ignore into journalissuearticles values(VOCO Xtra-fil); 4 mm çapında ve 4 mm yüksekliğinde plastik kalıplar kullanılarak bir LED ışık cihazı ile seramik yüzeylerde polimerize edildi. Elde edilen örnekler 24 saat 37°C saf suda bekletildi. Bağlanma kuvvetleri bir universal test cihazı kullanılarak makaslama testi ile ölçüldü. Kaydedilen değerler tek yönlü varyans analizi insert ignore into journalissuearticles values(ANOVA); kullanılarak analiz edildi insert ignore into journalissuearticles values(p<0.05);. Kırılma tipleri bir stereo mikroskop yardımıyla tespit edildi. BULGULAR: En yüksek bağlanma dayanımı Suprinity+K+Qb insert ignore into journalissuearticles values(20.15 MPa); grubunda, en düşük bağlanma dayanımı e.max CAD+ZP+Qb insert ignore into journalissuearticles values(10.85 MPa); grubunda bulundu. Primer ve bağlayıcı ajanlar arasında herhangi bir fark bulunmazken insert ignore into journalissuearticles values(p>0.05);, seramikler arasında önemli derecede fark bulundu insert ignore into journalissuearticles values(p<0.05);. e.max CAD örneklerin bağlanma değerleri Suprinity ye göre anlamlı derecede daha düşük bulundu insert ignore into journalissuearticles values(p<0.05);. SONUÇ: Bu çalışmanın sınırları dahilinde; üniversal bağlayıcı ajanların tek başına kullanıldığı kontrol grubunun, BISCO Z-Prime Plus kullanılan gruplara benzer bağlanma sonuçları gösterdiği ve iki uygulamanın da klinik olarak yeterli bağlanma dayanımı sağladıkları belirlenmiştir. Üniversal bağlayıcı ajanlar, CAD/CAM seramiklerin kompozit rezin ile tamirinde klinik olarak tek başlarına kullanılabilir. Anahtar Kelimeler: Bağlanma Kuvveti, Kompozit, Üniversal Bond, Seramik THE EFFECT OF DIFFERENT UNIVERSAL BONDING AGENTS ON THE BOND STRENGTH OF CAD/CAM CERAMICS REPAIRED WITH COMPOSITE RESIN AIM: In this study, a primer and two bonding agents were used on two different CAD / CAM ceramics to evaluate the bond strength after repairing with composite resin. METHODS: 30 samples were prepared from CAD/CAM ceramic materials insert ignore into journalissuearticles values(VITA Suprinity and IPS e.max CAD);. 1 mm thick sections were cut from the ceramic blocks using a low speed diamond saw insert ignore into journalissuearticles values(ISOMET 1000); to obtain the samples. Then the ceramics were fixed to with cold cured acrylic and the surfaces were treated with 10% hydrofluoric acid for 1 min. According to the primer application, ceramics were divided into two groups: BISCO Z-Prime-ZP and control group without primer-K. According to the bonding agents applied, ceramics were further divided into 2 subgroups: 3M ESPE Single Bond Universal-Sb and KURARAY Clearfil Universal Bond Quick-Qb insert ignore into journalissuearticles values(n = 5);. 3M ESPE Single Bond Universal-Sb was applied to ceramics with a scrubbing for 20 seconds and thinned with air for 5 seconds and polymerized with LED device for 10 seconds. KURARAY Clearfil Universal Bond Quick-Qb was applied to ceramics with a scrubbing for 10 seconds and thinned with air for 5 seconds and polymerized with LED device for 10 seconds. A composite resin insert ignore into journalissuearticles values(VOCO Xtra-fil); was polymerized on ceramic surfaces with a LED device using 4 mm diameter and 4 mm height plastic molds. The obtained samples were stored for 24 hours at 37 ° C in distilled water. Bond strength values were measured by a shear bond test using a universal tester. The recorded values were analyzed using Univariate Analysis of Varianc e insert ignore into journalissuearticles values(ANOVA); . insert ignore into journalissuearticles values(p<0.05); The fracture types were detected using a stereo microscope. RESULTS: The highest bond strength was found in the group Suprinity + K + Qb insert ignore into journalissuearticles values(20.15 MPa);, with the lowest bond strength in the group of e.max CAD + ZP + Qb insert ignore into journalissuearticles values(10.85 MPa);. There was no significant difference between the primer groups and bonding agent groups insert ignore into journalissuearticles values(p>0.05);, but there was a significant difference between the ceramics insert ignore into journalissuearticles values(p<0.05);. The bond strength values of e.max CAD samples were significantly lower than Suprinity samples. insert ignore into journalissuearticles values(p<0.05); CONCLUSION: Within the limits of this study; The control group using the universal bonding agents were shown to exhibit similar bonding results to those group used BISCO Z-Prime Plus and that both applications provided clinically sufficient bond strength. Universal bonding agents can be used alone in the clinical repair of CAD/CAM ceramics with composite resin. Keywords: Bond Strength, Ceramics, Composite, Universal BondKeywords : Bağlanma Kuvveti, Kompozit, Üniversal Bond