IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Current Research in Dental Sciences
  • Volume:29 Issue:3
  • FARKLI DEZENFEKSİYON YÖNTEMLERİNİN CAD / CAM VE KONVANSİYONEL AKRİLİK REZİNLERİN YÜZEY SERTLİĞİNE ET...

FARKLI DEZENFEKSİYON YÖNTEMLERİNİN CAD / CAM VE KONVANSİYONEL AKRİLİK REZİNLERİN YÜZEY SERTLİĞİNE ETKİSİ

Authors : Süleyman Çağatay DAYAN
Pages : 468-473
Doi:10.17567/ataunidfd.548800
View : 17 | Download : 9
Publication Date : 2019-07-16
Article Type : Research Paper
Abstract :Amaç: Bu çalışmanın amacı, farklı dezenfeksiyon yöntemlerinin insert ignore into journalissuearticles values(%2 glutaraldehit, %5 sodyum hipoklorit ve mikrodalga); yeni üretilen prefabrike olarak polimerize edilmiş CAD/CAM akrilik rezin, ısı ile ve kimyasal polimerize olan akrilik rezinlerin yüzey sertliği üzerindeki etkisini değerlendirmektir. Gereç ve yöntem:   15 mm çapında 2 mm kalınlığında disk şeklinde hazırlanan örnekler kontrol ve 3 farklı test grubuna ayrılmıştır insert ignore into journalissuearticles values(n = 8);: Grup 1: kontrol, 37°C\`de distile su içinde; Grup 2: %2’lik glutaraldehit; Grup 3: %5’lik sodyum hipoklorit; Grup 4: mikrodalga dezenfeksiyonu insert ignore into journalissuearticles values(650 W / 6 dak);. G2 ve G3 örnekleri bir saat boyunca dezenfektan solüsyonda bekletilmiştir. Yüzey sertliği ölçümleri insert ignore into journalissuearticles values(Vickers Sertliği);, 2 yönlü ANOVA ve Tukey’s Honestly Significant Difference testi insert ignore into journalissuearticles values(α=.05); kullanılarak analiz edilmiştir. Bulgular: Tüm gruplarda en yüksek yüzey sertlik değerleri kontrol gruplarında bulunmuştur. Prefabrike olarak polimerize edilmiş CAD/CAM akrilik rezinler bütün gruplarda en yüksek yüzey sertliği göstermiştir insert ignore into journalissuearticles values(p<0,001);. %5’lik sodyum hipoklorit dezenfeksiyonu, ısı ile ve kimyasal polimerize olan akrilik rezinlerin yüzey sertliği üzerinde etkili olmuştur insert ignore into journalissuearticles values(p <0,001);. Sonuçlar: Bu çalışmanın sınırları dahilinde, yeni üretilen prefabrike olarak polimerize edilmiş CAD/CAM akrilik rezinlerin yüzey sertliği, dezenfektan yöntemlerinden bağımsız olarak dezenfeksiyondan etkilenmemiştir. Anahtar Kelimeler: Akrilik rezin, Dezenfektan solüsyon, Dezenfeksiyon, CAD/CAM akrilik, Protez Kaide Materyali   Effect of Various Disinfection Methods on the Surface Hardness of CAD/CAM and Conventional Acrylic Resins ABSTRACT Objectives: The aim of the current study was to assess the effect of simulated disinfections insert ignore into journalissuearticles values(2% glutaraldehyde, 5% sodium hypochlorite, and microwave); on the surface hardness of newly introduced pre-polymerized acrylic resin, heat and self cured acrylic resin. Materials and Methods: Disc shaped specimens, 15 mm diameter and 2 mm thickness, were divided into a control and 3 test groups insert ignore into journalissuearticles values(n=8);: Group 1: control, stored in distilled water at 37°C; Group 2: 2% glutaraldehyde; Group 3: 5% sodium hypochlorite;   Group 4: microwave disinfection insert ignore into journalissuearticles values(650 W/6 min);. G1 to G3 were immersed for an hour in the disinfectant solution. Measurements of surface hardness insert ignore into journalissuearticles values(Vickers Hardness); were analyzed using 2-way ANOVA and Tukey’s Honestly Significant Difference insert ignore into journalissuearticles values(HSD); test insert ignore into journalissuearticles values(α=.05);. Results: The control groups showed the highest surface hardness values in all groups . Pre-polymerized block acrylic resin showed the highest surface hardness in all of the groups insert ignore into journalissuearticles values(p<0,001);. The 5% sodium hypochlorite disinfection had an effect on the surface hardness of heat and self cured acrylic resins insert ignore into journalissuearticles values(p<0,001);. Conclusions: Within the limitation of the current study, surface hardness of newly introduced pre-polymerized acrylic resin was not affected by disinfection regardless of the disinfectant methods. Keywords: Acrylic resin, Disinfectant solution, Disinfection, CAD/CAM acrylic, Denture Base Material
Keywords : Akrilik rezin, Dezenfektan solüsyon, Dezenfeksiyon, CAD CAM akrilik

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025