IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • European Mechanical Science
  • Volume:7 Issue:1
  • Effects of vacuum infusion configuration on homogeneity of glass fiber reinforced polymer composites...

Effects of vacuum infusion configuration on homogeneity of glass fiber reinforced polymer composites for automotive components

Authors : Şafak YILDIZHAN
Pages : 1-6
Doi:10.26701/ems.1166710
View : 15 | Download : 10
Publication Date : 2023-03-20
Article Type : Research Paper
Abstract :In this study, the effects of vacuum infusion configuration on the homogeneities of glass fiber reinforced vinyl ester composites have been evaluated. Three different sizes of samples insert ignore into journalissuearticles values(100x100, 500x500, and 1000x1000 mm); were fabricated. Three different configurations were used to fabricate the samples. The first two configurations had one inlet, while the third configuration had two inlets for resin infusion. Thickness variations and hardness insert ignore into journalissuearticles values(Shore D); measurements were performed to determine the homogeneities of the samples. The results revealed that, for small size samples, the configurations have no obvious effect on the homogeneity of the samples, both in terms of thickness variations and hardness values. However, for larger samples, the configuration where the resin is introduced into the preform in the center of the component showed better homogeneity than other configurations. Even a better distribution is assessed with the introduction of the resin in the center of the sample, although this configuration also resulted in thickness swellings in the central areas of the sample. The thickness swellings were observed around the inlet areas for all configurations. The study shows that the resin flow in the center of the component is preferable but thickness swelling must be considered when dimensional tolerances are critical.
Keywords : Vacuum Infusion Configuration, Homogeneity, Glass Fiber Composite, Automotive

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025