IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Environmental Research and Technology
  • Volume:7 Issue:2
  • PbO2 /graphite and graphene/carbon fiber as an electrochemical cell for oxidation of organic contami...

PbO2 /graphite and graphene/carbon fiber as an electrochemical cell for oxidation of organic contaminants in refinery wastewater by electrofenton process; electrodes preparation, characterization and performance

Authors : Rowaida Abbas, Ammar S Abbas
Pages : 175-185
Doi:10.35208/ert.1378232
View : 84 | Download : 105
Publication Date : 2024-06-30
Article Type : Research Paper
Abstract :The electro-Fenton oxidation process was used to treat organic pollutants in industrial wastewater as it is one of the most efficient advanced oxidation processes. The novel cell in this process consists of a prepared PbO2 electrode by electrodeposition on graphite substrate and carbon fiber modified with graphene as a cathode. X-ray diffraction, fluorescence, analysis system, atomic force microscopy, and scan electron microscopy were used to characterize the prepared anode and cathode. XRD patterns clearly show the characteristic reflection of the mixture of  - and β phases of PbO2 on graphite and carbon fiber, and AFM results for cathode and anode present that PbO2 on graphite substrate and graphene on carbon fiber surface are on a nanoscale. Contact angle measurement was determined for the carbon fiber cathode before and after modification. The anodic polarization curve showed a higher anodic current when utilizing the PbO2 anode than the graphite anode. Phenol in simulated wastewater was removed by electro-Fenton oxidation at 8 mA/cm2 current density, 0.4 mM of ferrous ion concentration at 35 °C up to 6 h of electrolysis. Chemical oxygen demand for the treated solution was removed by 94.02 % using the cell consisting of modified anode and cathode compared with 81.23% using modified anode and unmodified cathode and 79.87 % when using unmodified anode and modified cathode.
Keywords : Phenol removal, graphene, electro fenton, oxidation, carbon fiber, graphite

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025