IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Natural and Engineering Sciences
  • Volume:2 Issue:3
  • Poly(N-Methylpyrrole)-Chitosan layers for Glucose Oxidase Immobilization for Amperometric Glucose Bi...

Poly(N-Methylpyrrole)-Chitosan layers for Glucose Oxidase Immobilization for Amperometric Glucose Biosensor Design

Authors : Gul Ozyilmaz, Ali Tuncay Özyılmaz, Rağibe Hülya Akyürekoğlu
Pages : 123-134
Doi:10.28978/nesciences.354825
View : 40 | Download : 19
Publication Date : 2017-11-11
Article Type : Research Paper
Abstract :In this study, Pt electrode was coated by polyinsert ignore into journalissuearticles values(N-methypyrrol); insert ignore into journalissuearticles values(PNMP); film, then Glucose Oxidase insert ignore into journalissuearticles values(GOD); was immobilized onto PNMP layer with thin chitosan insert ignore into journalissuearticles values(Chi); gel, and finally, the electrode was reacted with glutaraldehyde insert ignore into journalissuearticles values(GAL); to form crosslinking between –NH2 groups of Chi and GOD to prevent enzyme leakage from Chi. GOD-based electrode was used to measure current response depending on glucose concentration by chronoamperometric method. The preparation of electrode conditions have significant effect on current values which were measured and optimized in presence of glucose, polymer synthesis and GOD immobilization conditions. Therefore, the effect of N-methylpyrrole monomer concentration, scan rate, Chi concentration, GOD concentration and GAL concentration on biosensor response were investigated by classical method. In sight of obtained data, optimal monomer concentration and scan rates for PNMP synthesis were determined as 50 mM and 20 mV/s, respectively. Optimal Chi, GOD and GAL concentrations were found as 1,00%, 4 mg/mL and 0.025 %, respectively. SEM images of Pt, PNMP coated Pt and GOD immobilized Pt electrodes were obtained. After 20 successive uses of same enzyme electrode in 5 mM glucose solution, it was still its 91.3 % of initial activity.
Keywords : Glucose, poly N methylpyrrole, amperometric biosensor, glucose oxidase, Chitosan

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025