  • Investigation of Outdoor Air Temperature Effects on Heat Recovery in Cross Flow Heat Exchanger

Investigation of Outdoor Air Temperature Effects on Heat Recovery in Cross Flow Heat Exchanger

Authors : Ramazan SELVER
Pages : 571-589
Doi:10.18185/erzifbed.1327981
View : 40 | Download : 59
Publication Date : 2023-08-31
Article Type : Research Paper
Abstract :A heat recovery device was designed and manufactured to provide air-to-air heat transfer by using a cross-flow heat exchanger on the pipe bundles. For this purpose, different cold air inlet temperature values and the temperature values of high temperature hot exhaust gases in the tube bundle heat exchanger were determined as operating parameters. According to the temperature increase of the cold air entering the heat exchanger; The kinematic viscosity values of the air increased and the maximum Reynolds number in the flow state of the air passing through the test heat exchanger was decreased. The average Nusselt numbers and average air convection coefficients in the flow of air decreased according to the temperature increase of the cold air. According to the temperature increase of the cold air entering the heat exchanger, both the analytical and experimental outlet temperature values of the cold air leaving the heat exchanger increase very close to each other. With this increase, the amount of heat transferred from the fluid to the fluid in the heat exchanger decreases. While the temperature value of the cold air entering the heat exchanger increases, the temperature difference value of the advancing air from the beginning to the outlet insert ignore into journalissuearticles values(ΔT= Ts – Ti); decreases. Due to this decrease, a decrease was observed in the amount of heat transfer.
Keywords : cross flow heat exchanger, heat recovery, industrial waste heat, pipe bundles

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025