IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
  • Volume:17 Issue:3
  • Investigation of Influencing Factors on Power Generation Performance in Reverse Electrodialysis

Investigation of Influencing Factors on Power Generation Performance in Reverse Electrodialysis

Authors : Aydın Cihanoğlu
Pages : 853-869
Doi:10.18185/erzifbed.1578766
View : 60 | Download : 94
Publication Date : 2024-12-31
Article Type : Research Paper
Abstract :The importance of meeting energy demands from renewable sources is growing daily. Reverse electrodialysis (RED) is a membrane-based technology that produces energy using electrolyte solutions with different salinities. This study has generated energy from the RED system using the commercial Fujifilm Type II ion exchange membranes (IEMs). Many parameters affect the power generation performance of the RED system. This study systematically investigated the parameters, the presence of divalent ions and organic molecules, the electrolyte solution concentration, and the flow velocity. The flow velocity results indicated that energy efficiency increased with increasing flow velocity of the electrolyte solutions. The presence of divalent ions created uphill transport. The results showed that increasing the mole ratio of divalent ions in the feed electrolyte solutions dramatically decreased the RED system performance due to increasing resistances. The organic fouling test of the anion exchange membranes (AEMs) was carried out using a real humic and fulvic acid mixture under static conditions. The results indicated that fouling layers formed in the AEMs structure, and these layers decreased by 30% of RED performance. Lastly, the RED system\\\'s long-term performance was tested for 4 hours at a constant current density of 8 A/m2 before and after AEM fouling experiments. The results revealed the fouling layers severely reduced the power generation performance of the RED system.
Keywords : reverse electrodialysis, ion exchange membrane, uphill transport, organic fouling, blue energy

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025