IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Genel Tıp Dergisi
  • Volume:34 Issue:3
  • Does Proteinuria Measured by Dipstick Method Reflect Reality in Patients with Preeclampsia?

Does Proteinuria Measured by Dipstick Method Reflect Reality in Patients with Preeclampsia?

Authors : Cenk Soysal, Mehmet Murat Işıkalan
Pages : 283-288
Doi:10.54005/geneltip.1361235
View : 78 | Download : 97
Publication Date : 2024-06-30
Article Type : Research Paper
Abstract :Aim: The aim of our study is to compare the proteinuria levels measured by dipstick in complete urine analysis at admission with the proteinuria levels measured in 24-hour collected urine for patients hospitalized with a presumptive diagnosis of preeclampsia. By doing so, we intend to review the reliability of the widely used dipstick proteinuria in patients with preeclampsia. Material ve Metod: Urine specimens were obtained from 70 pregnant women visiting high-risk maternity centers at a third-level healthcare institution. Patients were divided into four groups based on their urine dipstick screening test results: negative, +1, +2, +3, and higher. Proteinuria was considered to be present if the urinary dipstick test showed +1 or higher, while protein levels measured in the 24-hour urine collection were considered to indicate proteinuria if they exceeded 300 mg. The degree of correlation between the urine dipstick test and both 24-hour urine samples and spot urine protein-to-creatinine ratio (Pr/Cr) was compared. Results: The mean age of the 70 preeclampsia patients in the study group was 31.7±6.2, and the mean gestational age was 32.5±4.6. The dipstick test was found to have a sensitivity of 81.4% and a specificity of 85.2%. The dipstick test results were grouped as 0, +1, +2, +3, and higher. Statistically significant differences were detected among the groups in terms of systolic blood pressure, diastolic blood pressure, the amount of protein in the 24-hour urine, and spot urine Pr/Cr (p=0.001, p<0.001, p<0.001, p<0.001, respectively). When examining the correlation between the urine dipstick test and both 24-hour urine samples and spot urine Pr/Cr, a moderate correlation was found (r=0.65, p<0.001, r=0.55, p<0.001, respectively). Conclusion: In hypertensive pregnant individuals, urine dipstick tests demonstrated inadequate performance in ruling out preeclampsia. Consequently, according to our investigation, we posit that the dipstick urine test can be employed as a routine and dependable diagnostic tool for preeclampsia due to its rapid results and cost-effectiveness.
Keywords : Diagnostik test, dipstick, proteinüri, preeklampsi, sensitivite, spesifite

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025