IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi
  • Issue:21 - Aralık
  • Is Ultrasound-Guided Percutaneous Nephrostomy Efficacious and Safe in Pregnant Patients?: A Single C...

Is Ultrasound-Guided Percutaneous Nephrostomy Efficacious and Safe in Pregnant Patients?: A Single Center Experience

Authors : Ilhan Nahit Mutlu, Ali Dablan, Mehmet Cingöz, Tuğçe Arslanoğlu, Özgür Kiliçkesmez
Pages : 843-853
Doi:10.38079/igusabder.1366562
View : 98 | Download : 71
Publication Date : 2024-01-05
Article Type : Research Paper
Abstract :Aim: To evaluate the safety and efficacy of ultrasound-guided percutaneous nephrostomy (PCN) placement in pregnancy. Method: Medical records of 26 pregnant patients who were inserted with a total of 27 PCN catheters between June 2020 to June 2023 were retrospectively analyzed to assess imaging findings, procedural parameters, technical success, delivery outcomes, and procedural complications. Results: At the time of placement of the PCN, the mean gestational age was 29.04±7.01 weeks (range 7 - 36 weeks). The indications for insertion of the PCN catheter included: 1) obstructing calculi (46.2%), 2) pyelonephritis (34.6%), and 3) symptomatic hydronephrosis without calculi (19.2%). Successful catheter placement was achieved in 25/27 procedures, yielding a success rate of 92.59%, and no major complications. Minor instances of transient hematuria were encountered in three cases. The mean duration of catheter retention was 72.58 days. All patients exhibited significant clinical and symptomatic improvement. Among these patients, 22 patients (84.6%) delivered their babies at full-term, 3 patients (11.5%) delivered prematurely, and 1 patient (3.8%) experienced a miscarriage. Conclusion: Ultrasound-guided PCN placement is a reliable method with high success and efficacy that can be applied during pregnancy. This procedure avoids the use of ionizing radiation, ensuring safety for both the fetus and the mother.
Keywords : Hidronefroz, nefrostomi, perkütan, gebelik

ORIGINAL ARTICLE URL

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2026