IAD Index of Academic Documents
  • Home Page
  • About
    • About Izmir Academy Association
    • About IAD Index
    • IAD Team
    • IAD Logos and Links
    • Policies
    • Contact
  • Submit A Journal
  • Submit A Conference
  • Submit Paper/Book
    • Submit a Preprint
    • Submit a Book
  • Contact
  • Akdeniz Tıp Dergisi
  • Volume:10 Issue:2
  • The Effect of Preoperative Anxiety on Hemodynamic Parameters in Cesarean Section Under Spinal Anesth...

The Effect of Preoperative Anxiety on Hemodynamic Parameters in Cesarean Section Under Spinal Anesthesia

Authors : Cihan Sanbirgan, Nurten Kayacan, Bilge Karslı
Pages : 230-236
Doi:10.53394/akd.1199396
View : 43 | Download : 42
Publication Date : 2024-05-01
Article Type : Research Paper
Abstract :Purpose:Our aim of this study is to assess the effect of preoperative anxiety on intraoperative hypotension, postoperative recovery and maternal satisfaction in cesarean section under spinal anaesthesia. Methods:In this study,105 cesarean sections were included between aged of 18-45 and at 34-42 gestational weeks. Two different scales were used for the anxiety evaluation performed 1 hour before the operation, including STAI (I-II) anxiety score and Verbal Analoque scale (VAS). It was evaluated as low, moderate and high anxiety according to the scores obtained: low (20-37), moderate (38-44) and high (45-80) for STAI and low (0-3), moderate (4-6) and high (7-10) for VAS. During the operation, haemodynamic parameters were monitored at 5,10,15,20,30 minutes. In the post-operative first day, STAI-I, VAS, Post-Cesarean Mother Satisfaction Scale (PCMSS) and Post-Cesarean Recovery Scale (PCRS) were also evaluated. Results:In the evaluation of preoperative STAI -I and VAS anxiety scores, it was observed that the majority of cases had moderate anxiety group (61.9%, and 45.7%). There was no significant correlation between preoperative STAI-I, STAI-II, VAS anxiety levels and SSAM, SSDS in our study. There was a negative correlation between postoperative VAS anxiety scores and SSAM but this was not significant. In our study, no significant difference was found in umbilical cord pH values in different anxiety levels. In preoperative high VAS levels, MBP decreased significantly in 30 minutes, and also vasopressor requirement decreased significantly in preoperative low VAS anxiety levels (p<0.05). Conclusion:Anxiety level of the patients should be reduced through non-pharmacological methods in preoperative visits considering the fact that patients are pregnant. Further studies with a larger samples size should be performed to demonstrate clearly the effect of maternal anxiety on the hypotension during spinal anesthesia for cesarean section.
Keywords : Anestezi, Spinal, Hemodinamik ölçümler, Anksiyete

ORIGINAL ARTICLE URL
VIEW PAPER (PDF)

* There may have been changes in the journal, article,conference, book, preprint etc. informations. Therefore, it would be appropriate to follow the information on the official page of the source. The information here is shared for informational purposes. IAD is not responsible for incorrect or missing information.


Index of Academic Documents
İzmir Academy Association
CopyRight © 2023-2025